Стр. 660 - ARES

Упрощенная HTML-версия

ATTENTION:
Wiring of LED luminaires run in constant current and connected in series (scheme 1): Never connect the luminaire to a switched on power supply. Always connect luminaires to the power supply, and only
after connect the power supply to the mains.
ATTENTION:
Connection schemes: luminaires in constant current must always be connected in series; luminaires in constant tension must always be connected in parallel. Always respect polarity according to the DC
system.
ATTENTION:
Power Supplies must always match installation features: Never use a constant current power supply on a constant tension luminaire and vice versa.
ATTENTION:
The choice of the power supply must take into account the real power consumption of the luminaire (data shown in the catalogue) with a 20% increase to face any potential loss on the installation.
LED Luminaires and power supplies are protected against interferences and on the line, it is anyway highly recommended to set dedicated feeding lines to avoid any potential sudden and
severe interference (inductive loads like pumps or discharge lamps) that are likely to damage the LED module.
POWER SUPPLY
CONSTANT
VOLTAGE
MAINS
POWER SUPPLY
CONSTANT
CURRENT
MAINS
110-240V
110-240V
1-10V
15mt max distance
between power supply
and farest push
POWER SUPPLY
24V DIMMABLE
cod 129/135
POWER SUPPLY
24V DIMMABLE
cod 129/135
PUSH
PUSH
OPTION 1
OPTION 2
110-240V
110-240V
1-10V
15mt max distance
between power supply
and farest push
PUSH
OPTION 1
OPTION 2
POWER SUPPLY
24V DIMMABLE
cod 144
POWER SUPPLY
24V DIMMABLE
cod 144
PUSH
Tecnical schemes
Wiring diagram and sample series installation
Wiring diagram and sample dimmable series installation
Wiring diagram and sample dimmable parallel installation
Wiring diagram and sample parallel installation
657
2013