Стр. 236 - OSRAM_lamp_2014

Упрощенная HTML-версия

5.34
1
l
d
LUMILUX
®
CHIP control
®
T8
Tubular fluorescent lamps 26 mm, with G13 bases, for UV-sensitive applications
Product
reference
Product
number
L 18 W/62
4008321232700
18
970
62
590
B
12
1
L 36 W/62
4008321232724
36
2300
62
1200
B
12
1
L 58 W/62
4008321232748
58
3830
62
1500
B
12
1
Product features
Excellent filter at 500 nm
Long sleeve life (corresponds to the average life of
the lamp)
Average lifetime: 20,000 h with preheat ECG
Product benefits
Excellent UV filter
Areas of application
Microchip fabrication plants
Where UV and blue components have to be reduced
to the absolute minimum
Industry
Outdoor applications only in suitable luminaires
Equipment / Accessories
Suitable for use in open and enclosed luminaires
References / Links
For more information on the system guarantee and
the terms and conditions of the guarantee visit
www.osram.com/system-guarantee
For more information on QUICKTRONIC
®
electronic
control gear go to www.osram.com/QUICKTRONIC
Safety advice
Lamps with plastic sleeves, ambient temperature range:
-10…+80 °C
Lamps with plastic sleeves, maximum shelf life: 5 years
at 0…30 °C
Lamps with plastic sleeves must be replaced after
average life time (B50) has been reached
In case of lamp breakage: www.osram.com/
brokenlamp
Under standard conditions acc. IEC (free burning,
25 - 40°C ambient temperature) a typical increase of
the emitted radiation power in the wavelength range
< 500 nm up to 3 mW/klm per 10,000 hours of
operation was determined. This corresponds to approx.
0.1% of the total emitted radiation power. This increase
depends on the operation conditions.
For example for a T5 HO lamp at 80°C ambient
temperature an increase of the emitted radiation
power in the wavelength range < 500 nm of up to
50 mW/klm per 10,000 hours of operation can be
observed. This corresponds to approx. 2% of the
total emitted radiation power.
For applications in photo sensitive areas, routine
maintenance is necessary. This must include
verification of the amount of short wavelength light
emitted, and, if required, lamp replacement.