Стр. 370 - OSRAM_lamp_2014

Упрощенная HTML-версия

9.30
Consumption with
QTi DALI DIM
Consumption with
standard DALI-ECG
100 %
1 %
Luminous flux
3.5W
System output
4.5W
59W
61.5W
Savings
Consumption
Potential savings in electricitz costs
Relamping
Time
100%
0
Energy
QTi dimmable – DALI or 1…10 V interface
The current generation (GII) of dimmable QUICKTRONIC
®
Intelligent control gear with DALI (Digital Addressable
Lighting Interface) or 1…10 V interface (QTi DALI/DIM):
Automatic lamp detection by intelligent multilamp
operation and use of a large number of different lamps
J
Flexible luminaires and reduction of number of
ECG types
Maximum energy efficiency. Especially low standby
consumption for OSRAM DALI ECG.
Energy Efficiency Index EEI=A1 BAT
Very low standby consumption:
· QTi DALI 1x, 2x: 0.2 W (AC & DC operation)
· QTi DALI 3x, 4x: < 0.5 W (AC & DC operation)
Switching and dimming has no influence on lamp
lifespan
Optimum preheating at any dimming setting
Dimming range: 1…100% luminous flux
Outstanding flexibility and quality.
Amalgam and longlife lamps
Dimming to 1 % with T5 / T5 CONSTANT, T5 Energy
Saver and T5 XT Longlife lamps
Large number of additional ECG/lamp combinations
(OSRAM DULUX
®
L…HE, XT)
Up to 100,000 h service life at T c =65 °C, at max.
10 % failure
Suitable for luminaires with protection class I
Optimized lamp hot start within 0.5 s
OSRAM CFL and T5 CONSTANT lamps: dimming in
outdoor applications possible
Maximum efficiency of OSRAM dimming ECGs of up
to 94% thanks to high-efficiency components and
temperature-dependent cut-off. For dimmer settings
> 80% disconnection of electrode heating
J
Additional energy savings of up to 4 W (depending
on type)
CORRIDOR FUNCTION for direct connection of the
ECG to standard motion sensors (or free configuration)
Touch DIM
®
operation for up to 20 DALI ECGs
Fit for SMART GRID for feedback of mains power
input and lamp operating hours
Fit for Emergency function (automatic detection of
emergency light operation via ECG can be set)
QUICKTRONIC
®
INTELLIGENT dimmable QTi (DALI)…DIM
With a 2x HO 49 W luminaire, at an electricity price of
0.10 €/kWh, 20 € is additionally saved over its lamp life
span merely with the planning factor adjustment (0.8):
10 % of 110 W x 18,000 h x 0.10 €/kWh = 20 €/luminaire
in 4 years. This adjustment can be via the building ma-
nagement system or a light sensor.
Values related to the same luminous flux (Ballast Lumen Factor) (BLF) for
all QTi DIM = 1.0
90
80
70
60
50
40
30
20
10
0
System wattage [W]
internal ECG losses
Filament heating
Lamp wattage
62
4-lamp 18 W
Standard DIM EVG
78 W
4
12
65
4-lamp 18 W
OSRAM QTi DIM EVG
70 W
8 W savings
5
cut
off
QTi DIM electronic control gear from OSRAM is
renowned for its optimized system efficiency
Comparison between a T5 fluorescent lamp (54 W)
on QTi DALI DIM and one on a standard DALI ECG
Adjustment of the planning factor (0.8) thanks to the
use of dimmable ECGs saves an additional 10% in
electricity costs
CORRIDOR
FUNCTION
TOUCH DIM
SMART
GRID
EL