Стр. 387 - OSRAM_lamp_2014

Упрощенная HTML-версия

9.47
1
b
h
l
1
l
QUICKTRONIC
®
PROFESSIONAL –
ECG for T5/16 mm lamps
Product
reference
Product
number
a
T
QTP5 1X14…35
4008321329035
1xHE 14
1x1200
0.08
16
0,90 c
-20…+50
176…276
1xHE 21
1x1900
0.11
24
0,95
-20…+50
1xHE 28
1x2600
0.14
31
0,96
-20…+50
1xHE 35
1x3300
0.17
38
0,97
-20…+50
1xDL 28 HE
1x2550
0.13
28
0,95
-20…+50
QTP5 1X49
4008321329370
1xHO 49
1x4300
0.24
53
0,95
-20…+50
176…276
QTP5 1X80
4008321329059
1xHO 80
1x6150
0.38
86
0,98
-20…+50
176…276
1xDL 80
1x6000
0.38
86
0,98
-20…+50
QTP5 2X14…35
4008321329073
2xHE 14
2x1200
0.14
30
0,98
-20…+50
176…276
2xHE 21
2x1900
0.20
45
0,98
-20…+50
2xHE 28
2x2600
0.26
60
0,98
-20…+50
2xHE 35
2x3300
0.33
75
0,98
-20…+50
2xDL 28 HE
2x2525
0.26
56
0,98
-20…+50
QTP5 2X49
4008321329431
2xHO 49
2x4300
0.49
106
0,99
-20…+50
176…276
QTP5 3X14,4X14
4008321484598
3xHE 14
3x1200
0.22
48
0,95
-20…+50
176…276
4xHE 14
4x1200
0.28
70
0,97
-20…+50
Product
reference
QTP5 1X14…35
40…50
280
30
21
270
20
1
QTP5 1X49
40…50
280
30
21
270
20
1
QTP5 1X80
40…50
360
30
21
350
20
1
QTP5 2X14…35
40…50
360
30
21
350
20
1
QTP5 2X49
40…50
360
30
21
350
20
1
QTP5 3X14,4X14
40…50
280
40
21
270
20
1
Product features
Supply voltage: 220…240 V
Line voltage: 198…264 V
Line frequency: 0 Hz / 50 Hz / 60 Hz
Lamp start with optimum filament preheating
Lifetime: up to 100,000 h
(temperature at T c = 65 °C, max. 10 % failure rate)
Energy Efficiency Index EEI: A2 BAT
Automatic shutdown of defective lamps and at end
of life (EoL T.2)
Lamp operation: to EN 60929
Safety: to EN 61347-2-3
Product benefits
Long lamp life
No adverse effect from frequent on/off switching
Automatic restart after lamp replacement
Perfect lamp start for applications with motion
sensors
VDE/VDE EMC certified system
Very high energy efficiency due to cut-off technology
Areas of application
Emergency lighting systems acc. to EN 50172 /
DIN VDE 0108-100
Industry
Open-plan offices, corridors and storage rooms
Public buildings
Sports halls and factories
Strip lighting
Suitable for emergency lighting (DC operation)
Suitable for luminaires of protection class I and II
Suitable for indoor installations
Modernization of existing systems